Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Chinese Journal of Clinical Laboratory Science ; (12): 166-170, 2018.
Article in Chinese | WPRIM | ID: wpr-694820

ABSTRACT

Objective To evaluate the creditability of warning message of white differential count (WDF) and white precursor cell (WPC) channels in Sysmex XN-3000 hematology analyzer,and verify its optimal threshold and adjust the alarm threshold.Methods A total of 61 EDTA-K2 anticoagulated blood samples without abnormal warning and 521 EDTA-K2 anticoagulated blood samples with abnormal warning were simultaneously detected in WDF and WPC channels.After the smear specimens of blood sample were automatically prepared by the instrument,microscopic examinations were performed manually.The results of microscopic examination were considered as the gold standard to determine the reliability of the warning message from the instrument and verify the reasonability of initial warning threshold value provided by the manufacture.Consequently,the threshold values were adjusted based on the requirements in practical work.Results The warning messages of atypical lymphocytes and blasts/abnormal lymphocytes in WDF channel were higher sensitive (95.8% and 100% respectively),but lower specific (34.7% and 23.5% respectively) compared with microscopic examination.The warning messages of atypical lymphocyte,blasts and abnormal lymphocytes in WPC channel were lower sensitive (81.3%,66.7%,and 76.5% respectively) but higher specific (61.9%,55.5% and 88.3 % respectively) compared with microscopic examination.According to the ROC curve analysis,the prognostic values of warning message of microscopic examination were of medium level,except the warning message for abnormal lymphocytes was poor compared with WPC channel.Combining the practical retest rules,the optimal critical threshold values of atypical lymphocytes and blasts/Abn lymph in WDF channel were adjusted as 120,and they were adjusted as 140 in WPC channel.Conclusion The high sensitive WDF channel should first be used for screening,and the detectable warning message could be retested by using high specific WPC channel to shorten the turnaround time of the test results and improve the working efficiency.The initial critical warning threshold provided by the manufacture should be verified and adjusted to the optimum critical threshold in order to ensure the accuracy of test results.

2.
Journal of Zhejiang University. Medical sciences ; (6): 127-133, 2017.
Article in Chinese | WPRIM | ID: wpr-819081

ABSTRACT

To synthesize 5-fluorouracil-nicotinamide (5-FU-NCT) cocrystal and to investigate its physicochemical and biological properties. The cocrystal of 5-Fu-NCT was prepared through the cooling technology. PXRD, NMR, FTIR and DSC were used to characterize the structure of 5-FU-NCT cocrystal. Solubility was measured by HPLC method. Drug resistant human liver cancer BEL-7402/5-FU cells were treated with 5-FU-NCT cocrystal, the inhibition effect was tested by MTT and HE staining, and cancer cell migration was determined by scratch test. According to PXRD, NMR, FTIR and DSC results, the cocrystal of 5-Fu-NCT had been synthesized successfully. The characteristic diffraction peaks (2θ/°) of the cocrystal were 16.4, 20.4, 22.3, 27.9 and 30.1. The solubility of 5-FU-NCT was 13.5 g/L as measured by HPLC. The antitumor activity tests showed that 5-FU-NCT cocrystal enhanced anticancer effect of 5-FU, and the IC50 of 5-FU and 5-FU-NCT was 129.6 μg/mL and 42.6 μg/mL, respectively. 5-Fu-NCT cocrystal have been synthesized successfully through the cooling technology and it shows an enhanced anticancer effect in comparison to 5-FU on BEL-7402/5-FU cells.


Subject(s)
Humans , Antineoplastic Agents , Pharmacology , Cell Line, Tumor , Cell Movement , Cell Survival , Crystallization , Fluorouracil , Chemistry , Liver Neoplasms , Niacinamide , Chemistry , Solubility
3.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-591318

ABSTRACT

Objective To present a new algorithm for multidimensional medical image registration from global registration to local registration in sequence. Methods Firstly, the global registration was achieved by the method of affine transformation composed of B-splines,whose knots were the four vertexes of the medical image. Then the knots of the B-splines were increased, and the transformation function was more complex and elastic than ever,which completed the elastic aligning for the detail of the medical image. Results The whole registration algorithm represented the principle aligning from global registration to local registration. Conclusion It is proved by experiments that the presented algorithm can decrease the time of calculation and increase the robustness of registration.

SELECTION OF CITATIONS
SEARCH DETAIL